To help personalise content, tailor your experience and help us improve our services, Bisinfotech.com uses cookies.
By navigating our site, you agree to allow us to use cookies, in accordance with our Privacy Policy.

Teledyne Confirms Approval of its EV12DS480 Digital-to-analog Converter

Teledyne e2v has recently confirmed during its participation at Space Tech Expo that its EV12DS480 digital-to-analog converter (DAC) has been approved for use in space applications after it experienced irradiation tests.

TeledyneThe EV12DS480 is a 12-bit 8 GSps DAC, now ready for space applications, designed for Newspace systems and offered in various reliability grades (including NASA Grade 1).

This new DAC provides an analog bandwidth extending beyond 7GHz facilitating multi-band, direct digital synthesis up to K-band (26.5GHz).The series of tests included Total Ionizing Dose (TID) and Heavy Ions (HI) measurements. The tests were carried out to show that electronic components are capable of performing in a harsh space environment.

TID tests were performed to evaluate the functionality and performance parameter drifts of the Device Under Test (DUT). Heavy Ions tests were conducted at the RADiation Effects Facility (RADEF), specialized in applied research around nuclear and accelerator based technologies.

The HI tests evaluate the Single Event Latch-up (SEL) and Single Event Effects, which include Single Event Upset (SEU), Single Event Functional Interrupts (SEFI), and Single Event Transient (SET). These tests are important to ensure continuity and minimize drift.

“Tests on several EV12DS480 DAC devices are still underway with a dose rate of 10 mrad/s, with neither failure, nor parameter drift up to 100 krad(Si). Teledyne e2v is planning to continue testing up to a targeted cumulative dose of 150 krad(Si).” says Romain Pilard, Application Engineer from Teledyne e2v.

Exposure to heavy ions has allowed Teledyne e2v to draw the following conclusions: no SEL was detected during the irradiation with a LET of 60 MeV.cm²/mg, with no tilt; SETs were observed during the irradiation from 3.6 MeV.cm²/mg to 69.3 MeV.cm²/mg; SEFI were observed during the irradiation from 3.6 MeV.cm²/mg to 69.3 MeV.cm²/mg but all these SEFI were successfully managed by software reconfiguration of the DAC registers (no RESET, no power-up cycle required).

Tags

Nitisha Dubey

A diligent writer, who has been working from last five years in the same field. She has covered lots of event and expo for travel & judiciary, now covering technology. Book reading, exploring different destinations and varieties of cuisine are some hobbies. Love to watch biographies and historical movies.